Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters

Introduction. Photovoltaic (PV) power plants are subject to various forms of degradation that can impair their performance and lead to significant faults within PV systems. Among these, Potential-Induced Degradation (PID) stands out as one of the most severe, impacting the efficiency and output of P...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2025
Hauptverfasser: Khammassi, Z., Khaterchi, H., Zaafouri, A.
Format: Artikel
Sprache:English
Veröffentlicht: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2025
Schlagworte:
Online Zugang:http://eie.khpi.edu.ua/article/view/316529
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-316529
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2025-07-01T21:38:09Z
collection OJS
language English
topic potential-induced degradation
insulation resistance
maximum power point tracking
solar photovoltaic system
spellingShingle potential-induced degradation
insulation resistance
maximum power point tracking
solar photovoltaic system
Khammassi, Z.
Khaterchi, H.
Zaafouri, A.
Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
topic_facet potential-induced degradation
insulation resistance
maximum power point tracking
solar photovoltaic system
потенціально-індукована деградація
опір ізоляції
відстеження точки максимальної потужності
сонячна фотоелектрична система
format Article
author Khammassi, Z.
Khaterchi, H.
Zaafouri, A.
author_facet Khammassi, Z.
Khaterchi, H.
Zaafouri, A.
author_sort Khammassi, Z.
title Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_short Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_full Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_fullStr Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_full_unstemmed Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_sort experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
title_alt Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters
description Introduction. Photovoltaic (PV) power plants are subject to various forms of degradation that can impair their performance and lead to significant faults within PV systems. Among these, Potential-Induced Degradation (PID) stands out as one of the most severe, impacting the efficiency and output of PV generators while shortening their lifespan. Problem. This phenomenon is the result of a decrease in the shunt resistance of the cells encapsulated within the PV module, directly associated with a reduction in its insulation resistance. Although extensive research has been conducted in this area, our understanding of the factors contributing to PID, as well as its detection and effects on PV systems, remains incomplete. The goal of this work is to investigate the variations in insulation resistance at the module’s glass and frame, and to map the changes in shunt resistance at the module level to identify the most vulnerable areas, characterized by lower insulation resistance values and significantly affected by PID. Methodology. This study utilizes a comparative experimental method to investigate the behavior of two identical PV modules under similar climatic conditions, where one module is exposed to voltage stress while the other remains unstressed. A high-voltage insulation resistance tester was employed to apply voltage stress between the terminals of the stressed module and its metal frame, with insulation resistance systematically measured at various points to analyze changes in electrical properties. The originality of this study lies in the estimation of the shunt resistance based on the operating voltage of the PV string, which depends on the types of grounding, climatic conditions such as temperature and humidity, as well as the position of the cell within the PV module. This estimation is correlated with the I-V characteristic curves of two PV modules, one of which is subjected to operating voltages under well-controlled environmental conditions. The results reveal that an increase in the test voltage leads to a reduction in insulation resistance, a phenomenon that becomes more pronounced in humid environments. This highlights the vulnerability of PV modules to PID, which can significantly affect their lifespan and performance, particularly through the reduction of shunt resistance and the distortion of the characteristic curve of the stressed module affected by this phenomenon, thereby causing increased difficulty in extracting its maximum power. References 30, table 3, figures 17.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2025
url http://eie.khpi.edu.ua/article/view/316529
work_keys_str_mv AT khammassiz experimentalanalysisoftheeffectsofpotentialinduceddegradationonphotovoltaicmoduleperformanceparameters
AT khaterchih experimentalanalysisoftheeffectsofpotentialinduceddegradationonphotovoltaicmoduleperformanceparameters
AT zaafouria experimentalanalysisoftheeffectsofpotentialinduceddegradationonphotovoltaicmoduleperformanceparameters
first_indexed 2025-07-17T11:50:33Z
last_indexed 2025-07-17T11:50:33Z
_version_ 1838500170024615936
spelling eiekhpieduua-article-3165292025-07-01T21:38:09Z Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters Experimental analysis of the effects of potential-induced degradation on photovoltaic module performance parameters Khammassi, Z. Khaterchi, H. Zaafouri, A. potential-induced degradation insulation resistance maximum power point tracking solar photovoltaic system потенціально-індукована деградація опір ізоляції відстеження точки максимальної потужності сонячна фотоелектрична система Introduction. Photovoltaic (PV) power plants are subject to various forms of degradation that can impair their performance and lead to significant faults within PV systems. Among these, Potential-Induced Degradation (PID) stands out as one of the most severe, impacting the efficiency and output of PV generators while shortening their lifespan. Problem. This phenomenon is the result of a decrease in the shunt resistance of the cells encapsulated within the PV module, directly associated with a reduction in its insulation resistance. Although extensive research has been conducted in this area, our understanding of the factors contributing to PID, as well as its detection and effects on PV systems, remains incomplete. The goal of this work is to investigate the variations in insulation resistance at the module’s glass and frame, and to map the changes in shunt resistance at the module level to identify the most vulnerable areas, characterized by lower insulation resistance values and significantly affected by PID. Methodology. This study utilizes a comparative experimental method to investigate the behavior of two identical PV modules under similar climatic conditions, where one module is exposed to voltage stress while the other remains unstressed. A high-voltage insulation resistance tester was employed to apply voltage stress between the terminals of the stressed module and its metal frame, with insulation resistance systematically measured at various points to analyze changes in electrical properties. The originality of this study lies in the estimation of the shunt resistance based on the operating voltage of the PV string, which depends on the types of grounding, climatic conditions such as temperature and humidity, as well as the position of the cell within the PV module. This estimation is correlated with the I-V characteristic curves of two PV modules, one of which is subjected to operating voltages under well-controlled environmental conditions. The results reveal that an increase in the test voltage leads to a reduction in insulation resistance, a phenomenon that becomes more pronounced in humid environments. This highlights the vulnerability of PV modules to PID, which can significantly affect their lifespan and performance, particularly through the reduction of shunt resistance and the distortion of the characteristic curve of the stressed module affected by this phenomenon, thereby causing increased difficulty in extracting its maximum power. References 30, table 3, figures 17. Вступ. Фотоелектричні (PV) електростанції схильні до різних форм деградації, які можуть погіршити їхню продуктивність і призвести до значних несправностей у PV системах. Серед них потенціально-індукована деградація (PID), виділяється як одна з найсерйозніших, впливаючи на ефективність та вихідну потужність PV генераторів, одночасно скорочуючи термін їхньої служби. Проблема. Це явище є результатом зниження опору шунтуючого з’єднання елементів, вбудованих у PV модулі, що безпосередньо пов’язано зі зниженням опору його ізоляції. Хоча в цій галузі було проведено широкі дослідження, наше розуміння факторів, що сприяють PID, а також його виявлення та впливу на PV системи, залишається неповним. Метою роботи є дослідження змін опору ізоляції на склі та каркасі модуля, а також картографування змін опору шунтуючого з’єднання на рівні модуля для виявлення найбільш вразливих зон, що характеризуються нижчими значеннями опору ізоляції та значно зазнають впливу PID. Методологія. У цьому дослідженні використовується порівняльний експериментальний метод для дослідження поведінки двох ідентичних PV модулів за подібних кліматичних умов, де один модуль піддається впливу напруги, а інший залишається ненапруженим. Для застосування напруги між клемами напруженого модуля та його металевим каркасом було використано високовольтний тестер опору ізоляції, при цьому опір ізоляції систематично вимірювався в різних точках для аналізу змін електричних властивостей. Оригінальність дослідження полягає в оцінці опору шунту на основі робочої напруги PV кола, яка залежить від типів заземлення, кліматичних умов, таких як температура та вологість, а також положення елемента всередині PV модуля. Ця оцінка корелює з ВАХ двох PV модулів, один з яких піддається робочій напрузі в добре контрольованих умовах навколишнього середовища. Результати показують, що збільшення випробувальної напруги призводить до зниження опору ізоляції, явище, яке стає більш вираженим у вологому середовищі. Це підкреслює вразливість PV модулів до PID, що може суттєво вплинути на їхній термін служби та продуктивність, зокрема через зменшення опору шунту та спотворення характеристик модуля, що піддається впливу цього явища, що призводить до збільшення труднощів в отриманні його максимальної потужності. Бібл. 30, табл. 3, рис. 17. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2025-07-02 Article Article application/pdf http://eie.khpi.edu.ua/article/view/316529 10.20998/2074-272X.2025.4.05 Electrical Engineering & Electromechanics; No. 4 (2025); 35-43 Электротехника и Электромеханика; № 4 (2025); 35-43 Електротехніка і Електромеханіка; № 4 (2025); 35-43 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/316529/322113 Copyright (c) 2025 Z. Khammassi, H. Khaterchi, A. Zaafouri http://creativecommons.org/licenses/by-nc/4.0