Soft X-ray measurement by SPPD11-04 detectors on the PF “Tulip” installation

The soft X-ray (SXR) measurements were received with help of the fast semiconductor detectors SPPD11-04 with exposure time about 1.5 ns. Observation directions were at 45° and 90° to the chamber axis. The SXR dependence from pressure was designed. The radiation maximum corresponded to argon pressure...

Full description

Saved in:
Bibliographic Details
Date:2008
Main Authors: Eliseev, S.P., Nikulin, V.Ya., Silin, P.V.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2008
Series:Вопросы атомной науки и техники
Subjects:
Online Access:http://dspace.nbuv.gov.ua/handle/123456789/111026
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Soft X-ray measurement by SPPD11-04 detectors on the PF “Tulip” installation / S.P. Eliseev, V.Ya. Nikulin, P.V. Silin // Вопросы атомной науки и техники. — 2008. — № 6. — С. 222-224. — Бібліогр.: 2 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Description
Summary:The soft X-ray (SXR) measurements were received with help of the fast semiconductor detectors SPPD11-04 with exposure time about 1.5 ns. Observation directions were at 45° and 90° to the chamber axis. The SXR dependence from pressure was designed. The radiation maximum corresponded to argon pressure equals to 2 Torr. The full width at half-maximum of the pulse at this pressure and a voltage of 12 kV was 5 ns. The SXR radiation dependence was investigated from the capacitor banks voltage (8-14 kV) in the two ranges of energy 1.2-1.8 and 2.9-3.5 keV. At the voltage of 14 kV and an argon pressure of 2 Torr the quantity of radiation quanta was estimated about 8·10¹⁴, the total radiation energy ~ 0.2 J and power ~ 7·10⁶ W in 4π geometry.