Thermoluminescence response of Ge-, Al- and Nd-doped optical fibers by 6 MeV - electron and 6 MV - photon irradiations

In this paper, we report the prediction of thermoluminescence responses of Neodymium-doped SiO₂ optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6MeV - electron irradiations without requirement for experimental measurements. A technique has been developed to calculate prediction of 6M...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2015
Hauptverfasser: Hossain, I., Saeed, M.A., Wagiran, H., Hida, N., Yaakob, N.H., Moburak, A.A.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2015
Schriftenreihe:Вопросы атомной науки и техники
Schlagworte:
Online Zugang:http://dspace.nbuv.gov.ua/handle/123456789/112122
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Thermoluminescence response of Ge-, Al- and Nd-doped optical fibers by 6 MeV - electron and 6 MV - photon irradiations / I. Hossain, M.A. Saeed, H.Wagiran, N. Hida, N.H. Yaakob, A A.Moburak // Вопросы атомной науки и техники. — 2015. — № 3. — С. 65-68. — Бібліогр.: 10 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:In this paper, we report the prediction of thermoluminescence responses of Neodymium-doped SiO₂ optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6MeV - electron irradiations without requirement for experimental measurements. A technique has been developed to calculate prediction of 6MeV - electron response of Neodymium-doped SiO₂ optical fibre by observing the measured TL response of 6MV - photon and the ratio of known measured photon/electron yield ratio distribution for Ge-doped, Al-doped optical fibre and standard TLD 100 dosimeter. The samples were kept in gelatin capsule an irradiated with 6MV - photon at the dose range from 0.5 Gy to 4.0 Gy. Siemens model Primus 3368 linear accelerator located at Hospital Sultan Ismail, Johor Bahru has been used to deliver the photon beam to the samples. We found the average response ratio of 6MV - photon and 6MeV - electron in Ge-doped, Al-doped optical fibre and standard TLD-100 dosimeter are 0.83(3). Observing the measured value of 6MV - photon irradiation this average ratio is useful to find the prediction of thermoluminescence responses by 6MeV - electron irradiation of Neodymium-doped SiO₂ optical fibre by the requirement for experimental measurements with various dose ranges from 0.5 Gy to 4.0 Gy by 6MV - photon irradiations.