Thin film PZT-Si structure with quadrant-diagonal electrode system as an element of position sensitive pyroelectric detector

The main characteristics of position sensitive systems of pyroelectric detectors of radiation (PDR) with sensitive elements based on PZT film on Si-substrate were investigated by photopyromodulation method. Pt-PZT-Pt/Ti-SiO₂/Si structures with 1.9 mm (111)-oriented PZT (54/46) layer were manufacture...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2002
Hauptverfasser: Bravina, S.L., Cattan, E., Morozovsky, N.V., Remiens, D.
Format: Artikel
Sprache:English
Veröffentlicht: Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України 2002
Schriftenreihe:Semiconductor Physics Quantum Electronics & Optoelectronics
Online Zugang:http://dspace.nbuv.gov.ua/handle/123456789/121122
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Thin film PZT-Si structure with quadrant-diagonal electrode system as an element of position sensitive pyroelectric detector / S.L. Bravina, E. Cattan, N.V. Morozovsky, D. Remiens // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2002. — Т. 5, № 1. — С. 89-94. — Бібліогр.: 7 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:The main characteristics of position sensitive systems of pyroelectric detectors of radiation (PDR) with sensitive elements based on PZT film on Si-substrate were investigated by photopyromodulation method. Pt-PZT-Pt/Ti-SiO₂/Si structures with 1.9 mm (111)-oriented PZT (54/46) layer were manufactured by R.F. magnetron sputtering. Top Pt electrodes in a shape of isosceles rectangular triangle together make the quadrant-diagonal system. The results of pyroelectric undersurface probing and “along surface” pyroelectric scanning show that the investigated quadrant-diagonal system of SE makes it possible to examine all main types of differential position-sensitive PDR. The experimental results for investigated 2-element single-coordinate PDR variants are in a good agreement with calculations for the corresponding systems.