Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions

The possibility of using nanoporous composite system based on biogenic hydroxyapatite (BHA), which alloyed by ferromagnetic additives due to using two methods of physicochemical mixing, as a carrier of drugs for orthopedics and traumatology was shown. It was found that the sample obtained by precipi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2017
Hauptverfasser: Otychenko, O.M., Babutina, T.Ye., Kuda, O.A., Budylina, O.M., Protsenko, L.S., Koval, O.Yu., Uvarova, I.V.
Format: Artikel
Sprache:English
Veröffentlicht: НТК «Інститут монокристалів» НАН України 2017
Schriftenreihe:Functional Materials
Schlagworte:
Online Zugang:http://dspace.nbuv.gov.ua/handle/123456789/136858
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions / O.M. Otychenko, T.Ye. Babutina, O.A. Kuda, O.M. Budylina, L.S. Protsenko, O.Yu. Koval, I.V. Uvarova // Functional Materials. — 2017. — Т. 24, № 4. — С. 577-583. — Бібліогр.: 30 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-136858
record_format dspace
fulltext
spelling irk-123456789-1368582018-06-17T03:10:48Z Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions Otychenko, O.M. Babutina, T.Ye. Kuda, O.A. Budylina, O.M. Protsenko, L.S. Koval, O.Yu. Uvarova, I.V. Characterization and properties The possibility of using nanoporous composite system based on biogenic hydroxyapatite (BHA), which alloyed by ferromagnetic additives due to using two methods of physicochemical mixing, as a carrier of drugs for orthopedics and traumatology was shown. It was found that the sample obtained by precipitation previously prepared iron oxalate on the surface of BHA microspheres has a greater adsorption activity than the sample obtained by including BHA directly in the process of obtaining iron oxalate (300 and 175 mg/g respectively). However, due to the difference in porosity, they are capable to hold a different amount of the injected antibiotic mass: 6 mass.% - for material obtained by physico-mechanical method and 10 mass.% - for the sample obtained by chemical method. 2017 Article Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions / O.M. Otychenko, T.Ye. Babutina, O.A. Kuda, O.M. Budylina, L.S. Protsenko, O.Yu. Koval, I.V. Uvarova // Functional Materials. — 2017. — Т. 24, № 4. — С. 577-583. — Бібліогр.: 30 назв. — англ. 1027-5495 DOI: https://doi.org/10.15407/fm24.04.577 http://dspace.nbuv.gov.ua/handle/123456789/136858 en Functional Materials НТК «Інститут монокристалів» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Characterization and properties
Characterization and properties
spellingShingle Characterization and properties
Characterization and properties
Otychenko, O.M.
Babutina, T.Ye.
Kuda, O.A.
Budylina, O.M.
Protsenko, L.S.
Koval, O.Yu.
Uvarova, I.V.
Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
Functional Materials
description The possibility of using nanoporous composite system based on biogenic hydroxyapatite (BHA), which alloyed by ferromagnetic additives due to using two methods of physicochemical mixing, as a carrier of drugs for orthopedics and traumatology was shown. It was found that the sample obtained by precipitation previously prepared iron oxalate on the surface of BHA microspheres has a greater adsorption activity than the sample obtained by including BHA directly in the process of obtaining iron oxalate (300 and 175 mg/g respectively). However, due to the difference in porosity, they are capable to hold a different amount of the injected antibiotic mass: 6 mass.% - for material obtained by physico-mechanical method and 10 mass.% - for the sample obtained by chemical method.
format Article
author Otychenko, O.M.
Babutina, T.Ye.
Kuda, O.A.
Budylina, O.M.
Protsenko, L.S.
Koval, O.Yu.
Uvarova, I.V.
author_facet Otychenko, O.M.
Babutina, T.Ye.
Kuda, O.A.
Budylina, O.M.
Protsenko, L.S.
Koval, O.Yu.
Uvarova, I.V.
author_sort Otychenko, O.M.
title Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
title_short Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
title_full Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
title_fullStr Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
title_full_unstemmed Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
title_sort adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions
publisher НТК «Інститут монокристалів» НАН України
publishDate 2017
topic_facet Characterization and properties
url http://dspace.nbuv.gov.ua/handle/123456789/136858
citation_txt Adsorption of ceftriaxon by biogenic hydroxyapatite with magnetic additions / O.M. Otychenko, T.Ye. Babutina, O.A. Kuda, O.M. Budylina, L.S. Protsenko, O.Yu. Koval, I.V. Uvarova // Functional Materials. — 2017. — Т. 24, № 4. — С. 577-583. — Бібліогр.: 30 назв. — англ.
series Functional Materials
work_keys_str_mv AT otychenkoom adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT babutinatye adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT kudaoa adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT budylinaom adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT protsenkols adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT kovaloyu adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
AT uvarovaiv adsorptionofceftriaxonbybiogenichydroxyapatitewithmagneticadditions
first_indexed 2025-07-10T03:00:15Z
last_indexed 2025-07-10T03:00:15Z
_version_ 1837227285519794176