Optimization of a Compton direct-charge detector for monitoring high-energy bremsstrahlung radiation

The conditions of application of a Compton direct-charge detector (DCD) for monitoring of intensity of the highenergy bremsstrahlung (X-ray) radiation are studied. A method is described for calculation of characteristics of the secondary е,Х-radiation at exit of an electron accelerator, and also for...

Full description

Saved in:
Bibliographic Details
Date:2019
Main Authors: Nikiforov, V.I., Shlyakhov, I.N., Shevchenko, V.A., Tenishev, A.Eh., Uvarov, V.L.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2019
Series:Вопросы атомной науки и техники
Subjects:
Online Access:http://dspace.nbuv.gov.ua/handle/123456789/195481
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Optimization of a Compton direct-charge detector for monitoring high-energy bremsstrahlung radiation / V.I. Nikiforov, I.N. Shlyakhov, V.A. Shevchenko, A.Eh. Tenishev, V.L. Uvarov // Problems of atomic science and technology. — 2019. — № 6. — С. 158-162. — Бібліогр.: 8 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine