Recent developments in the ISTTOK heavy ion beam diagnostic

The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2016
Hauptverfasser: Nedzelskiy, I.S., Malaquias, A., Henriques, R.B., Sharma, R.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2016
Schriftenreihe:Вопросы атомной науки и техники
Schlagworte:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id oai:nasplib.isofts.kiev.ua:123456789-115467
record_format dspace
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Plasma diagnostics
Plasma diagnostics
spellingShingle Plasma diagnostics
Plasma diagnostics
Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
Recent developments in the ISTTOK heavy ion beam diagnostic
Вопросы атомной науки и техники
description The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma electrons and separated from the primaries due to the confining magnetic field of the plasma device. The resulting secondary ions are collected outside the plasma. The plasma parameters that can be measured by the HIBD are: the plasma electron density and temperature, and the electric and magnetic potentials. On the small tokamak ISTTOK (R = 0.46 m, a = 0.085 m, B = 0.5 T, Ip = 4…6 kA, = 5 × 10¹⁸ m ⁻³ , Te = 120 eV), the HIBD is based on a 20 keV Xe⁺ (or Cs⁺ ) beam injector and a multiple cell array detector (MCAD) collecting a fan of secondary Xe²⁺ (or Cs²⁺) ions emerging from the plasma along the primary beam trajectory. This paper describes the recent developments and improvements in the ISTTOK HIBD secondary beam detection. The capabilities of new detection system are illustrated by recent results of ISTTOK plasma MHD activity and electrode biasing studies. The on going developments of the multichannel multi-slit 90o cylindrical energy analyzer for the plasma potential and its fluctuations measurements and a novel approach of the HIBD use in real-time vertical plasma position control are also considered.
format Article
author Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
author_facet Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
author_sort Nedzelskiy, I.S.
title Recent developments in the ISTTOK heavy ion beam diagnostic
title_short Recent developments in the ISTTOK heavy ion beam diagnostic
title_full Recent developments in the ISTTOK heavy ion beam diagnostic
title_fullStr Recent developments in the ISTTOK heavy ion beam diagnostic
title_full_unstemmed Recent developments in the ISTTOK heavy ion beam diagnostic
title_sort recent developments in the isttok heavy ion beam diagnostic
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2016
topic_facet Plasma diagnostics
citation_txt Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ.
series Вопросы атомной науки и техники
work_keys_str_mv AT nedzelskiyis recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT malaquiasa recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT henriquesrb recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT sharmar recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT nedzelskiyis sovremennoesostoâniediagnostikiplazmypučkatâžëlyhionovnatokamakeisttok
AT malaquiasa sovremennoesostoâniediagnostikiplazmypučkatâžëlyhionovnatokamakeisttok
AT henriquesrb sovremennoesostoâniediagnostikiplazmypučkatâžëlyhionovnatokamakeisttok
AT sharmar sovremennoesostoâniediagnostikiplazmypučkatâžëlyhionovnatokamakeisttok
AT nedzelskiyis sučasnijstandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT malaquiasa sučasnijstandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT henriquesrb sučasnijstandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT sharmar sučasnijstandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
first_indexed 2025-07-22T04:09:16Z
last_indexed 2025-07-22T04:09:16Z
_version_ 1838318728765243392
spelling oai:nasplib.isofts.kiev.ua:123456789-1154672025-02-23T17:10:18Z Recent developments in the ISTTOK heavy ion beam diagnostic Современное состояние диагностики плазмы пучка тяжёлых ионов на токамаке ISTTOK Сучасний стан діагностики плазми пучка важких іонів на токамацi ISTTOK Nedzelskiy, I.S. Malaquias, A. Henriques, R.B. Sharma, R. Plasma diagnostics The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma electrons and separated from the primaries due to the confining magnetic field of the plasma device. The resulting secondary ions are collected outside the plasma. The plasma parameters that can be measured by the HIBD are: the plasma electron density and temperature, and the electric and magnetic potentials. On the small tokamak ISTTOK (R = 0.46 m, a = 0.085 m, B = 0.5 T, Ip = 4…6 kA, = 5 × 10¹⁸ m ⁻³ , Te = 120 eV), the HIBD is based on a 20 keV Xe⁺ (or Cs⁺ ) beam injector and a multiple cell array detector (MCAD) collecting a fan of secondary Xe²⁺ (or Cs²⁺) ions emerging from the plasma along the primary beam trajectory. This paper describes the recent developments and improvements in the ISTTOK HIBD secondary beam detection. The capabilities of new detection system are illustrated by recent results of ISTTOK plasma MHD activity and electrode biasing studies. The on going developments of the multichannel multi-slit 90o cylindrical energy analyzer for the plasma potential and its fluctuations measurements and a novel approach of the HIBD use in real-time vertical plasma position control are also considered. Диагностика пучком тяжёлых ионов (ДПТИ) является мощным инструментом в исследованиях горячей плазмы в термоядерных установках с магнитным удержанием. Инжектируемый в плазму первичный пучок однозарядных положительных ионов ионизируется в двухзарядное состояние в столкновениях с электронами плазмы. В магнитном поле плазменной установки результирующие вторичные ионы отделяются от первичного пучка и детектируются вне плазмы. Измеряемые ДПТИ параметры плазмы включают плотность, температуру электронов, электрический и магнитный потенциалы. На малом токамаке ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5 × 10¹⁸ м ⁻³, Te = 120 эВ) ДПТИ состоит из 20 кэВ инжектора Xe ⁺ (или Cs⁺) пучка и мультиколлекторного детектора (МКД) вторичных Хе²⁺ (или Cs²⁺ионов, выходящих из плазмы вдоль траектории первичного пучка. Описываются изменения и улучшения детекторной системы ДПТИ на токамаке ISTTOK. Возможности новой детекторной системы иллюстрируются недавними результатами исследований МГД-активности и поляризации плазмы. Рассматриваются также разработка многоканального мультищелевого 90o цилиндрического анализатора энергии для измерений потенциала плазмы и его флуктуаций и новый подход использования ДПТИ для контроля вертикального положения плазмы в режиме реального времени. Діагностика пучком важких іонів (ДПВІ) є потужним інструментом у дослідженнях гарячої плазми в термоядерних установках з магнітним утриманням. Iнжектований в плазму первинний пучок однозарядних позитивних іонів іонізується в двозарядний стан у зіткненнях з електронами плазми. У магнітному полі плазмової установки результуючі вторинні іони відокремлюються від первинного пучка і фіксуються поза плазми. Вимірювані ДПВІ параметри плазми включають щільність, температуру електронів, електричний і магнітний потенціали. На малому токамацi ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5×10¹⁸ м ⁻³, Te = 120 еВ) ДПВІ складається з 20 кеВ інжектора Xe+ (або Cs+ ) пучка і мультиколекторного детектора (МКД) вторинних Хе²⁺ (або Cs²⁺) іонів, які виходять з плазми уздовж траєкторії первинного пучка. Описуються зміни і поліпшення детекторной системи ДПВІ на токамацi ISTTOK. Можливості нової детекторної системи ілюструються недавніми результатами досліджень МГД-активності і поляризації плазми. Розглядаються також розробка багатоканального мультищілинного 90o циліндричного аналізатора енергії для вимірювань потенціалу плазми та його флуктуацій і новий підхід використання ДПВІ для контролю вертикального положення плазми в режимі реального часу IPFN activities received financial support from ”Fundação para a Ciência e Tecnologia” through project UID/FIS/50010/2013. 2016 Article Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ. 1562-6016 PACS: 52.55.Fa, 52.70.-m https://nasplib.isofts.kiev.ua/handle/123456789/115467 en Вопросы атомной науки и техники application/pdf Національний науковий центр «Харківський фізико-технічний інститут» НАН України