Beam position measurement for electron cooler EC-300 and EC-35

The beam position measurement system of EC-35 and EC-300 is presented in this paper. The electrostatic pickup is used for beam position measuring. The ion and electron currents have alternative part with the magnitude of about 1 mA. The important feature of the beam position measurement system (BP...

Full description

Saved in:
Bibliographic Details
Date:2006
Main Author: Bekhtenev, E.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2006
Series:Вопросы атомной науки и техники
Subjects:
Online Access:http://dspace.nbuv.gov.ua/handle/123456789/78863
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Beam position measurement for electron cooler EC-300 and EC-35 / E. Bekhtenev // Вопросы атомной науки и техники. — 2006. — № 2. — С. 108-109. — Бібліогр.: 2 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Description
Summary:The beam position measurement system of EC-35 and EC-300 is presented in this paper. The electrostatic pickup is used for beam position measuring. The ion and electron currents have alternative part with the magnitude of about 1 mA. The important feature of the beam position measurement system (BPM system) is simultaneous measurements of the positions of both the ion and the electron beams. The resolution of the beam position measurement is about 1 mm, diameter vacuum chamber 300 mm.