Beam position measurement for electron cooler EC-300 and EC-35
The beam position measurement system of EC-35 and EC-300 is presented in this paper. The electrostatic pickup is used for beam position measuring. The ion and electron currents have alternative part with the magnitude of about 1 mA. The important feature of the beam position measurement system (BP...
Saved in:
Date: | 2006 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
Series: | Вопросы атомной науки и техники |
Subjects: | |
Online Access: | http://dspace.nbuv.gov.ua/handle/123456789/78863 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Cite this: | Beam position measurement for electron cooler EC-300 and EC-35 / E. Bekhtenev // Вопросы атомной науки и техники. — 2006. — № 2. — С. 108-109. — Бібліогр.: 2 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of UkraineSummary: | The beam position measurement system of EC-35 and EC-300 is presented in this paper. The electrostatic pickup
is used for beam position measuring. The ion and electron currents have alternative part with the magnitude of
about 1 mA. The important feature of the beam position measurement system (BPM system) is simultaneous measurements
of the positions of both the ion and the electron beams. The resolution of the beam position measurement
is about 1 mm, diameter vacuum chamber 300 mm. |
---|