A high speed 140 ghz microwave interferometer for density fluctuation measurements in Uragan-2M stellarator
The operation of the 2 mm microwave superheterodyne interferometer, which allows to measure the linear electron density (average over the line of sight through the plasma) at the Uragan-2M stellarator is presented. Compared with the previously used 8 mm interferometer, this diagnostic does signi...
Gespeichert in:
Datum: | 2018 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | English |
Veröffentlicht: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2018
|
Schriftenreihe: | Вопросы атомной науки и техники |
Schlagworte: | |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Zitieren: | A high speed 140 ghz microwave interferometer for density fluctuation measurements in Uragan-2M stellarator / R.O. Pavlichenko, N.V. Zamanov, A.E. Kulaga and Uragan-2M team // Вопросы атомной науки и техники. — 2018. — № 6. — С. 332-335. — Бібліогр.: 10 назв. — англ. |