A high speed 140 ghz microwave interferometer for density fluctuation measurements in Uragan-2M stellarator

The operation of the 2 mm microwave superheterodyne interferometer, which allows to measure the linear electron density (average over the line of sight through the plasma) at the Uragan-2M stellarator is presented. Compared with the previously used 8 mm interferometer, this diagnostic does signi...

Full description

Saved in:
Bibliographic Details
Date:2018
Main Authors: Pavlichenko, R.O., Zamanov, N.V., Kulaga, A.E., Uragan-2M team
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2018
Series:Вопросы атомной науки и техники
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:A high speed 140 ghz microwave interferometer for density fluctuation measurements in Uragan-2M stellarator / R.O. Pavlichenko, N.V. Zamanov, A.E. Kulaga and Uragan-2M team // Вопросы атомной науки и техники. — 2018. — № 6. — С. 332-335. — Бібліогр.: 10 назв. — англ.