Thermal state of the rotor winding of the turbogenerator with direct hydrogen cooling
The temperature field of the rotor of the synchronous turbogenerator is investigated. The temperature distributions in rotor windings of 300 and 550-MW turbogenerators with direct hydrogen cooling of rotor winding are obtained. The transition to more power is implemented by increasing the hydrogen p...
Gespeichert in:
Datum: | 2015 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | Russian |
Veröffentlicht: |
Інститут енергетичних машин і систем ім. А. М. Підгорного Національної академії наук України
2015
|
Schlagworte: | |
Online Zugang: | https://journals.uran.ua/jme/article/view/57507 |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Назва журналу: | Energy Technologies & Resource Saving |